• Obsolete Operating Room Refurbishment Economic Scheme Air Purifier
  • Obsolete Operating Room Refurbishment Economic Scheme Air Purifier
  • Obsolete Operating Room Refurbishment Economic Scheme Air Purifier
  • Obsolete Operating Room Refurbishment Economic Scheme Air Purifier
  • Obsolete Operating Room Refurbishment Economic Scheme Air Purifier

Obsolete Operating Room Refurbishment Economic Scheme Air Purifier

Structure: Floor Standing
Usage: Medical
Air Volume: >400m³/h
Type: HEPA Filter
Certification: ISO
Application Area: >61m²
Samples:
US$ 1060/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
CJX-Y-2000
Power Source
Electrical
Operating Principle
Active
Purifying Technology
HEPA
Net Weight
56kg
Air Flow
Max 2000 M3/H
Disinfection
HEPA + UV
Housing
Metal
Flow Type
Laminar Flow
Timing
Yes
Reservation
Yes
Transport Package
Paper Carton/Wooden Case
Specification
700*500*1715mm
Trademark
Jiajing
Origin
China
HS Code
8422309090
Production Capacity
5000 Sets/Per

Product Description

Laminar Flow Air Purifier for Operating Room
 
Introduction
Laminar flow purification and disinfection machine is composed of medium-efficiency filter, fan, UV germicidal lamps and high-efficiency filter. Fan circulates air through every modules in the machine. Through UV disinfection and HEPA filtration, polluted air is cleaned.
Obsolete Operating Room Refurbishment Economic Scheme Air PurifierObsolete Operating Room Refurbishment Economic Scheme Air Purifier
Disinfection principle
* UV + HEPA 13
* Use high intensity UV rays to penetrate microorganisms, destroy protein structure to eliminate them.
* High efficiency HEPA 13 reducing microbes with size >0.3μm.

Function
* Running machine for 60 min in 150 m3 room, >90% airborne microorganisms can be eliminated.
* Running machine for 60 min in 150 m3 room, airborne particles amount (0.5 micron) size is 352000/m³, particles with size >5 micron 2930/m³, conform to GB 50333-2013 Architectural technical code for hospital clean operating department.


Application Scope

Applied to rooms accommodating patients suffering from burn, hematonosis, respiratory disease and other immunocompromised patients. Common wards with laminar flow machine installed can be an alternative to common operating room for its achieving cleanliness class 10,000 within 150 m3 room.
Obsolete Operating Room Refurbishment Economic Scheme Air Purifier

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
85
Year of Establishment
2016-12-21